{"product_id":"keyence-md-u1000-uv-laser-marker-enclosure-workstation","title":"Keyence MD-U1000 UV Laser Marker Enclosure \u0026 Workstation (MD-U1000C \/ MD-U1020C)","description":"\u003cdiv style=\"border:1.5px solid #14171A;padding:18px 20px;margin:0 0 22px;\"\u003e\n  \u003cp style=\"margin:0 0 6px;font-size:12px;letter-spacing:.14em;text-transform:uppercase;color:#C2410C;font-weight:600;\"\u003eBuilt to order · Quoted per build\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 12px;font-size:16px;line-height:1.5;\"\u003eEvery MD-U enclosure is engineered around your head, your parts and your floor. Send us the head model, what you're marking and where it will sit. You'll get a general-arrangement drawing and a written quote.\u003c\/p\u003e\n  \u003cp style=\"margin:0;\"\u003e\u003ca href=\"mailto:contact@clearviewplastic.com?subject=Keyence%20MD-U1000%20enclosure%20quote\u0026amp;body=Head%20model%20%28MD-U1000C%20\/%20MD-U1020C%29%3A%0ABenchtop%20enclosure%20or%20full%20workstation%3A%0AParts%20being%20marked%20%28material%2C%20largest%20size%29%3A%0AParts%20per%20shift%3A%0AFume%20extraction%20you%20have%20or%20need%3A%0AWho%20owns%20laser%20safety%20on%20site%20%28LSO%20\/%20EHS%29%3A%0AShip-to%20city%20and%20state%3A%0ATarget%20date%3A%0A\" style=\"display:inline-block;background:#14171A;color:#FFFFFF;text-decoration:none;font-weight:600;padding:12px 20px;margin:0 10px 8px 0;\"\u003eRequest a quote\u003c\/a\u003e\u003ca href=\"tel:+19162501143\" style=\"display:inline-block;color:#14171A;font-weight:600;padding:12px 4px;\"\u003e916-250-1143\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eKeyence MD-U1000 series\u003c\/strong\u003e is a 3-axis UV marker built for jobs fiber lasers can't do cleanly: cold marks on plastics, silicon, glass and coated parts, from a 355 nm source with 42 mm of built-in Z-range. It also ships as a \u003cstrong\u003eClass 4 laser product\u003c\/strong\u003e: a head, a separate controller, a key switch and a remote-interlock input. Nothing stands between the beam and the people working around it.\u003c\/p\u003e\n\u003cp\u003eThis is the housing that goes around it. We build an opaque aluminum-composite enclosure or a full workstation to the MD-U1000C or MD-U1020C mounting drawing. The door interlocks are wired to the head's own safety inputs, and the viewing window is matched to 355 nm. Extraction is sized to what you're marking. The head itself is never touched.\u003c\/p\u003e\n\n\u003ch2\u003eBuilt around the MD-U1000, not a generic galvo\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChamber height set from working distance.\u003c\/strong\u003e The MD-U1000C focuses at 189 ±21 mm over a 125 × 125 mm field; the MD-U1020C focuses at 300 ±21 mm over 330 × 330 mm. We stack working distance, Z-travel, your fixture and your tallest part, then add service clearance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHead mount machined to Keyence's pattern.\u003c\/strong\u003e The head is 145 × 469 × 230 mm and 18 kg, with a 6× M6 mounting face. It mounts to a rigid plate at a fixed, repeatable height, so your focus and your code grades stay put.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoom for the cable and the connector.\u003c\/strong\u003e The rear connector adds about 48 mm, and the cable needs a generous bend radius. We route the 4.3 m head cable through a sealed pass-through instead of pinching it at a door seam.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController bay with its own air.\u003c\/strong\u003e The MD-U1000 controller is a 280 × 405 × 421 mm, 23.5 kg forced-air unit that exhausts through the rear. It gets a ventilated bay within cable reach, with its air path kept separate from the fume stream. We follow the ventilation clearances in Keyence's installation manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBeam containment, scoped honestly\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpaque ACM walls.\u003c\/strong\u003e The walls are 1\/4\" aluminum composite panel, not clear plastic. The aluminum face helps block stray beams reflecting off metallic and glossy parts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWindow matched to 355 nm.\u003c\/strong\u003e The viewing window is laser-safety material specified for UV, and the window manufacturer's optical-density data ships with your documentation. You can also choose no window and monitor by camera.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterlocked doors.\u003c\/strong\u003e Door switches are fitted, wired and labeled to terminate at the MD-U's remote-interlock and shutter inputs; opening either circuit stops emission. We don't open, modify or rewire the head or the controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFume capture sized to the material\u003c\/h2\u003e\n\u003cp\u003eUV marking is chosen for plastics, and plastics are exactly what you don't want in the room air. PVC releases hydrogen chloride, ABS releases hydrogen cyanide and benzene, and acrylic gives off methyl methacrylate. The person loading parts eight hours a day breathes whatever the enclosure doesn't capture. Every MD-U build includes a source-capture port at the mark and an exhaust port sized to your extractor (4\" or 75 mm). A commercial-grade Donaldson BOFA extractor package is available when you want assurance, not just reduction.\u003c\/p\u003e\n\n\u003ch2\u003eConfigure your build (quoted)\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFit:\u003c\/strong\u003e MD-U1000C (standard area) or MD-U1020C (wide area)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFormat:\u003c\/strong\u003e benchtop enclosure over your existing bench, or a complete workstation with the enclosure on a base that has a controller bay, an extractor bay and storage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccess:\u003c\/strong\u003e front door standard; side doors for pass-through; part-load drawer; fixture plate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart height:\u003c\/strong\u003e fixed platform set to your part, or a lift table for mixed part heights\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eViewing:\u003c\/strong\u003e 355 nm laser-safety window, camera only, or both\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtraction:\u003c\/strong\u003e source-capture arm, 4\" or 75 mm port, Donaldson BOFA extractor package\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e flat-packed or delivered assembled\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eYour Keyence unit (published by Keyence)\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n  \u003ctr style=\"border-bottom:1px solid #D2D7DC;\"\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eModels\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003eMD-U1000C (standard area) · MD-U1020C (wide area)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #D2D7DC;\"\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eSource\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e355 nm UV (YVO4), 2.5 W at the focal point · Class 4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #D2D7DC;\"\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eField \/ working distance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e1000C: 125 × 125 × 42 mm @ 189 ±21 mm · 1020C: 330 × 330 × 42 mm @ 300 ±21 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #D2D7DC;\"\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eHead\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e145 × 469 × 230 mm · 18.0 kg · IP64 · 6× M6 mount\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"border-bottom:1px solid #D2D7DC;\"\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eController\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e280 × 405 × 421 mm · 23.5 kg · forced-air cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px 10px 6px 0;font-weight:600;\"\u003eHead cable\u003c\/td\u003e\n\u003ctd style=\"padding:6px 0;\"\u003e4.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:13px;color:#5C646D;\"\u003eRunning the newer MD-U2000 system (MD-U2010–MD-U2530 heads)? The head is larger (156 × 580.7 × 266 mm, 21–23 kg) and the controller is lighter, but the architecture is the same. Tell us your head model and we'll quote that fit.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWill this make my MD-U a Class 1 laser?\u003c\/strong\u003e\u003cbr\u003eNo enclosure sold on its own does that. Laser classification belongs to the finished laser system and its manufacturer under 21 CFR 1040.10. We build the protective housing and interlock provisions your safety plan calls for. Your laser safety officer gets the drawings, materials and window data for the ANSI Z136.1 evaluation. If your program needs a certified Class 1 system, tell us at the start and we'll plan it with you and your laser vendor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan you build it before our MD-U arrives?\u003c\/strong\u003e\u003cbr\u003eYes. We design from Keyence's published dimensions and mounting drawing, then confirm the mount and working distance against your unit before final assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you install or commission the laser?\u003c\/strong\u003e\u003cbr\u003eWe build and ship the enclosure with its drawings and interlock wiring diagram. Keyence's team or your integrator commissions the head, which keeps its certification and warranty with the company that made it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePOs and net terms?\u003c\/strong\u003e\u003cbr\u003eYes. We accept POs, ACH and cards, supply a W-9 on request, and offer net terms on qualifying orders.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#14171A;color:#FFFFFF;padding:18px 20px;margin:22px 0 0;\"\u003e\n  \u003cp style=\"margin:0 0 10px;font-size:18px;font-weight:600;color:#FFFFFF;\"\u003eSend the head model and the part. We'll scope the station.\u003c\/p\u003e\n  \u003cp style=\"margin:0;\"\u003e\u003ca href=\"mailto:contact@clearviewplastic.com?subject=Keyence%20MD-U1000%20enclosure%20quote\u0026amp;body=Head%20model%20%28MD-U1000C%20\/%20MD-U1020C%29%3A%0ABenchtop%20enclosure%20or%20full%20workstation%3A%0AParts%20being%20marked%20%28material%2C%20largest%20size%29%3A%0AParts%20per%20shift%3A%0AFume%20extraction%20you%20have%20or%20need%3A%0AWho%20owns%20laser%20safety%20on%20site%20%28LSO%20\/%20EHS%29%3A%0AShip-to%20city%20and%20state%3A%0ATarget%20date%3A%0A\" style=\"display:inline-block;background:#E8871A;color:#14171A;text-decoration:none;font-weight:600;padding:12px 20px;margin:0 10px 8px 0;\"\u003eRequest a quote\u003c\/a\u003e\u003ca href=\"mailto:contact@clearviewplastic.com\" style=\"color:#FFFFFF;\"\u003econtact@clearviewplastic.com\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:12px;color:#5C646D;margin-top:18px;\"\u003eImages show Clearview ACM laser marking enclosures and workstations as reference builds. Your MD-U enclosure is drawn to your unit. Keyence and MD-U are trademarks of Keyence Corporation. Clearview Plastics is an independent enclosure fabricator and is not affiliated with, authorized by or endorsed by Keyence; model names describe fit only. Clearview enclosures do not change the classification of the laser inside them. Made in California.\u003c\/p\u003e\n","brand":"Clearview Plastics","offers":[{"title":"Default Title","offer_id":49634405220590,"sku":"CV-KEY-MDU1000-ENC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0415\/4661\/2904\/files\/keyence-md-u1000-enclosure-reference-workstation.jpg?v=1790206119","url":"https:\/\/clearviewplastic.com\/products\/keyence-md-u1000-uv-laser-marker-enclosure-workstation","provider":"Clearview Plastics","version":"1.0","type":"link"}